Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Book Review
Brief Report
Case Letter
Case Report
Case Series
Commentary
Current Issue
Editorial
Erratum
Guest Editorial
Images
Images in Neurology
Images in Neuroscience
Images in Neurosciences
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Media and News
None
Notice of Retraction
Obituary
Original Article
Point of View
Position Paper
Review Article
Short Communication
Systematic Review
Systematic Review Article
Technical Note
Techniques in Neurosurgery
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Book Review
Brief Report
Case Letter
Case Report
Case Series
Commentary
Current Issue
Editorial
Erratum
Guest Editorial
Images
Images in Neurology
Images in Neuroscience
Images in Neurosciences
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Media and News
None
Notice of Retraction
Obituary
Original Article
Point of View
Position Paper
Review Article
Short Communication
Systematic Review
Systematic Review Article
Technical Note
Techniques in Neurosurgery
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Book Review
Brief Report
Case Letter
Case Report
Case Series
Commentary
Current Issue
Editorial
Erratum
Guest Editorial
Images
Images in Neurology
Images in Neuroscience
Images in Neurosciences
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Media and News
None
Notice of Retraction
Obituary
Original Article
Point of View
Position Paper
Review Article
Short Communication
Systematic Review
Systematic Review Article
Technical Note
Techniques in Neurosurgery
View/Download PDF

Translate this page into:

Original Article
5 (
3
); 254-257
doi:
10.4103/0976-3147.133577

Stent-assisted coiling of wide-necked intracranial aneurysms using the Solitaire AB stent

Division of Interventional Neurology and Stroke, Narayana Health Institute of Neurosciences, Bangalore, Karnataka, India
Department of Neurology, Narayana Health Institute of Neurosciences, Bangalore, Karnataka, India

Address for correspondence: Dr. Vikram Huded, Narayana Health Institute of Neurosciences, 258/A, Bommasandra Industrial Area, Hosur Main Road, Bangalore - 560 099, Karnataka, India. E-mail: drvikramhuded@gmail.com

Licence

This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Disclaimer:
This article was originally published by Medknow Publications & Media Pvt Ltd and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Context:

Stent-assisted coiling of wide-necked and complex intracranial aneurysms is an effective and feasible treatment option. The self-expanding, fully retrievable Solitaire AB (eV3, Irvine, CA, USA) stent is the latest neurovascular remodeling device available. To the best of our knowledge, there are no studies of Solitaire AB-assisted coiling of wide-necked intracranial aneurysms from India.

Aim:

Solitaire AB-assisted coiling of wide-necked intracranial aneurysms.

Materials and Methods:

The study was conducted in a tertiary care center with a dedicated Interventional Neurology division from 2009 to 2013. Consecutive patients with wide-necked aneurysms who underwent coiling assisted by the Solitaire AB stent were enrolled in the study. Axium 3D and Helix (eV3, Irvine, CA, USA) platinum coils were used to densely pack the aneurysm sac after deploying the stent across the neck. All patients were pretreated with antiplatelets according to protocol. Subsequently, dual antiplatelets were given for 6 months followed by continued aspirin. Outcome was assessed at 3 months using the modified Rankin Scale.

Statistical Analysis Used:

Statistical analysis was done using the SPSS 17.0 software.

Results:

A total of 16 patients underwent stent-assisted coiling. The most common site was the internal carotid artery (nine patients), median aneurysm size was 7 mm and median neck diameter was 5 mm. Thirteen patients presented with ruptured aneurysms. We achieved complete occlusion in all patients with no major complications. Thirteen patients were followed up, all have an mRS score of zero or one.

Conclusion:

We conclude that for wide-necked aneurysms, stent-assisted coiling using the Solitaire AB is a safe and effective treatment option.

Keywords

Aneurysm
coiling
intracranial
solitaire
stent-assisted

Introduction

Intracranial aneurysms can be treated either surgically by clipping or endovascularly by coiling. Endovascular coiling was validated as a treatment option in the International Subarachnoid Aneurysm Trial (ISAT).[1] Since then, endovascular coiling has become a standard of care. However, aneurysms with wide necks or complex morphology pose a challenge to this method of treatment. Development of endovascular remodeling devices or stents has revolutionized management of such aneurysms. Of the various remodeling devices available, the Solitaire AB self-expandable stent (eV3, Irvine, CA, USA) is the latest one.[2] We present our experience of stent-assisted coiling of wide-necked aneurysms in a tertiary care center from India. To the best of our knowledge, this is the first study from India using the Solitaire AB stent.

Materials and Methods

A database is maintained at our center for all patients undergoing endovascular procedures. The data were reviewed retrospectively from 2009 till date. Outpatient and inpatient records, procedural reports, and images were analyzed to determine anatomical and procedural details as well as adverse outcomes. All patients who were diagnosed with wide-necked aneurysms (neck diameter of 4 mm or more[2] or dome: Neck ratio less than two) and underwent stent-assisted coiling were included.

All patients were premedicated with antiplatelets before the procedure. Patients who presented with unruptured aneurysms were treated with aspirin 150 mg and clopidogrel 75 mg for 3 days before the procedure. Those patients who presented with subarachnoid hemorrhage were given 300 mg of clopidogrel and 325 mg of aspirin 2 h before the procedure. All procedures were done under general anesthesia and systemic heparinization. The right femoral percutaneous approach was used in all patients. A 3D angiogram was done to precisely define the configuration of the aneurysm. The Solitaire AB stent (eV3) was negotiated across the aneurysm neck using Rebar microcatheter (eV3). Another microcatheter was advanced into the aneurysm sac and jailed by deploying the stent.[3] Intravenous abxicimab 5 mg was given bolus after deployment of first two coils followed by intravenous infusion for 12 h in patients with recently ruptured aneurysm who developed filling defect in the stent during coiling. The aneurysm sac was then densely packed using platinum coils (Axium 3D and Helix; eV3). Postpacking angiogram was done to document exclusion of the aneurysm from the circulation. All patients were treated with aspirin 150 mg and clopidogrel 75 mg daily for 6 months and then continued on aspirin 150 mg for life. Outcome was assessed at discharge and then at 3 months using the modified Rankin Scale,[4] either by personal or telephonic interview.[5] Control angiograms were done where feasible 6 months after the coiling procedure. SPSS version 17.0 software was used to analyze the data.

Results

Patient characteristics

A total of 16 patients underwent stent-assisted coiling of wide-necked aneurysms at our center between 2009 and 2013, of whom four were males and 12 females. The mean age at presentation was 51 years. Thirteen patients presented with ruptured aneurysms and subarachnoid hemorrhage, two presented with unruptured aneurysms and headache, and one presented with an unruptured aneurysm and cranial nerve palsy.

Aneurysm size and locations

The characteristics of the aneurysms are outlined in table 1.

Table 1 Characteristics of the aneurysms

Immediate results

Stent deployment was successful in all the patients. Angiographic results included complete occlusion in all 16 patients (100%). There were no neck remnants and no incomplete occlusions.

Complications

Four patients had minimal filling defect in the stent during the procedure, which resolved with intravenous abxicimab. There were no embolic or hemorrhagic complications in any patient. There were no deaths.

Follow up

Modified Rankin Scale was zero or one in all patients at discharge. Followup examinations have been done in 13 out of 16 patients till date. All patients who were followed up had an mRS of zero or one at 3 months. Three patients who underwent procedures recently are awaiting followup. Followup control angiograms of 13 patients done at 6 months duration did not show any regrowth or in-stent stenosis [Figures 14].

Right vertebral angiogram showing wide neck basilar top aneurysm with small right PCA aneurysm
Figure 1
Right vertebral angiogram showing wide neck basilar top aneurysm with small right PCA aneurysm
Road map showing coil deployment after Y stenting
Figure 2
Road map showing coil deployment after Y stenting
Fluoroscopic image showing Y stent and coil mass
Figure 3
Fluoroscopic image showing Y stent and coil mass
Postcoiling angiogram showing complete exclusion of basilar top aneurysm from circulation with patent bilateral posterior cerebral artery
Figure 4
Postcoiling angiogram showing complete exclusion of basilar top aneurysm from circulation with patent bilateral posterior cerebral artery

Discussion

The availability of neurovascular remodeling devices has opened new avenues for endovascular treatment of wide-necked and complex intracranial aneurysms. Earlier stents had various limiting characteristics such as inability to reposition once deployed, requirement of stiff delivery catheters, and poor visibility.[2] The Solitaire AB stent is fully retrievable and can be redeployed to achieve optimal alignment across the neck of the aneurysm.

Studies have reported overall higher complication rates associated with stent-assisted coiling.[67] The complications may be hemorrhagic (subarachnoid and lobar), thromboembolic (related to the stent), or technical (failure of delivery or other technical issues).[7] These may be due to either the morphology of the aneurysm, difficulty in achieving complete occlusion, or as adverse effects of dual antiplatelet therapy.

There is sufficient literature regarding stent-assisted coiling using older stents.[891011] Only a few case series using the Solitaire stent have been published.[212] Our study is the first series from India with Solitaire-assisted aneurysm coiling. We were able to achieve optimal placement of the stent across the aneurysm neck in all patients. There were no technical failures.

A literature survey of stent-supported coiling published recently reported initial complete occlusion rates of 45% with a complication incidence of 19% and death incidence of 2.1%.[7] A recent study from China using the Solitaire stent reported an initial complete occlusion rate of 83.9% with complications in six out of 31 patients and three deaths.[2] We achieved complete occlusion in all patients with no morbidity and mortality.

Conclusion

In our experience, stent-assisted coiling using the Solitaire AB stent is a safe and effective method of treating wide-necked and complex intracranial aneurysms. We agree that our study is small and although we encountered no morbidity and mortality in our patients, larger studies with long-term follow-ups are required to assess the efficacy and outcomes of stent-assisted aneurysm treatment. Newer generations of endovascular devices may further expand the effectiveness and scope of endovascular treatment.

Source of Support: Nil.

Conflict of Interest: None declared.

References

  1. , , , , , , . Executive Committee of the American Society of Interventional and Therapeutic Neuroradiology; American Society of Neuroradiology. The International Subarachnoid Aneurysm Trial (ISAT): A position statement from the Executive Committee of the American Society of Interventional and Therapeutic Neuroradiology and the American Society of Neuroradiology. AJNR Am J Neuroradiol. 2003;24:1404-8.
    [Google Scholar]
  2. , , , , . Stent-assisted coil embolization of intracranial aneurysms using Solitaire stent. Neurol India. 2012;60:278-82.
    [Google Scholar]
  3. , , , , , . Comparison of techniques for stent assisted coil embolization of aneurysms. J Neurointerv Surg. 2012;4:339-44.
    [Google Scholar]
  4. , , , , , . Interobserver agreement for the assessment of handicap in stroke patients. Stroke. 1988;19:604-7.
    [Google Scholar]
  5. , , , , , . Reliability of the modified Rankin Scale applied by telephone. Neurol Int. 2013;5:e2.
    [Google Scholar]
  6. , , , , , , . Stent-assisted coiling in acutely ruptured intracranial aneurysms: A qualitative, systematic review of the literature. AJNR Am J Neuroradiol. 2011;32:1232-6.
    [Google Scholar]
  7. , , , , , . Stent-supported aneurysm coiling: A literature survey of treatment and follow-up. AJNR Am J Neuroradiol. 2012;33:159-63.
    [Google Scholar]
  8. , , , , , , . Anatomic results and complications of stent-assisted coil embolization of intracranial aneurysms. Interv Neuroradiol. 2008;14:267-84.
    [Google Scholar]
  9. , , , , , . Comparison of devices used for stent-assisted coiling of intracranial aneurysms. PloS One. 2011;6:e24875.
    [Google Scholar]
  10. , , , , , , . Neuroform stent-assisted coil embolization: A new treatment strategy for complex intracranial aneurysms. Results of medium length follow-up. Neurol Neurochir Pol. 2010;44:366-74.
    [Google Scholar]
  11. , , , , , , . Neuroform stent-assisted embolization of incidental anterior communicating artery aneurysms: Long-term clinical and angiographic follow-up. Neurosurgery. 2011;69:27-37.
    [Google Scholar]
  12. , , , , . Stent-assisted coil embolization of intracranial aneurysms using the Solitaire™ AB Neurovascular Remodeling Device: Initial and midterm follow-up results. Neuroradiology. 2013;55:629-38.
    [Google Scholar]
Show Sections